Zolix 라만 여기 레이저 Raman Excitation Laser
Narrow linewidth diode laser for Raman spectroscopy excitation
라만 분광 여기용 협선폭 다이오드 레이저
Description
SCS600 is the second-generation product of the high-performance solar cell quantum efficiency / spectral response measurement system developed by Zolix. It can measure solar cells of various materials and is suitable for universities, research institutes and, R D and production quality management in enterprises. Compared with the first-generation product, the software is more user-friendly and easy to operate. Compatible with high-precision Keithley 2612B and 2636B digital source meters, which improves the data acquisition accuracy and bias test capability. Larger sample chamber and double doors make it easier to place and replace samples. In addition, Zolix provides customized services, so that the equipment can better meet customer needs. Main Functions: ■ EQE, IQE/ Spectral Response/ IPCE ■ Integrated JSC ■ It can measure the sample in glove box, vacuum chamber and other equipment ■ Wide spectral measurement range: 250nm – 1700nm ■ Light beam induced current measurement ■ CCD camera monitoring ■ Bias light test and bias voltage test ■ Provide AC and DC double data acquisition functions System Features High stability light source, good system repeatability Adopting the substitution method, light source stability is an important reason that affects the repeatability of the measurement results. Due to the different spectral response ranges of the detectors, the system provides high stability xenon lamp, tungsten lamp light source, their stability is higher than 99%, that ensure high repeatability and accuracy of measurement results. Monitoring CCD Clearly observe the light spot and precisely locate the sample. Professional Optical Design Total reflection optical path without aberration makes the measurement result more accurate. Converging the broadband light source in the transmission mode will cause aberration, as shown in the figure below, the spot size of different wavelengths is different, when testing small area detectors, there will be a large deviation.
SCS600은 Zolix가 개발한 2세대 고성능 태양전지 양자효율(QE)/분광 응답(SR) 측정 시스템입니다. 다양한 소재의 태양전지를 단일 또는 모듈 형태로 측정할 수 있습니다.
Specifications
|
Model |
Wavelength ( nm ) |
Power ( mW ) |
|
M365L |
365 |
420 |
|
M405L |
405 |
400 |
|
M450L |
450 |
320 |
|
M550L |
550 |
50 |
|
M610L |
610 |
80 |
|
M690L |
690 |
100 |
|
M760L |
760 |
100 |
|
M880L |
880 |
50 |
|
M980L |
980 |
50 |
|
Model |
SCS600-XE |
SCS600-TH |
SCS600-XT |
|||
|
Light source |
Xenon light source |
Tungsten light source |
Dual light source |
|||
| Wavelength Range | 300-1100 nm (up to1700nm is option) |
400-2500 nm | 300-2500 nm | |||
| Wavelength Accuracy | ±0.2 nm | |||||
| Wavelength Repeatability | ±0.1 nm | |||||
| Minimum scanning step | 0.005 nm | |||||
| Diffraction gratings | One is 1200 lines/mm, one is 600 lines/mm, one is 300 lines/mm | |||||
| Motorized filter wheel | Automatically controlled by software | |||||
| Wavelength resolution | FWHM=0.1nm ( focal length: 300mm, grating: 1200g/mm, slit width: 0.01 mm ) | |||||
|
Repeatability |
200-400nm |
≤2% |
– |
≤2% |
||
|
400-1000nm |
≤1% |
≤1% |
≤1% |
|||
|
1000-1700nm |
≤1.5% |
≤1.5% |
≤1.5% @1000-2500nm |
|||
|
Test Conditions |
Standard Detector |
|||||
|
Light spot size |
1x1m㎡~10x10m㎡ |
|||||
| Sample dimensions | 50 X 50 m㎡ to 100 X 100 m㎡ | |||||
|
Model |
Function |
Application |
Maximum Sample Size |
Other Instruction |
|
IV-F1 |
Vacuum adsorption, suitable for large size cells |
IV measurement |
100mm*100mm |
|
|
IV-F2 |
Vacuum adsorption, suitable for small size cells |
IV measurement |
50mm*50mm |
|
|
QE-F4 |
Two sets of 3D adjustable probes, the base is an oxygen-free copper electrode |
QE measurement |
30mm*30mm |
Suitable for front electrode and double- sided electrode cell |
|
QE-F6-C |
3M test clip, 2D adjustable position |
IV/QE measurement |
100mm*100mm |
Suitable for dye-sensitized cells |
|
QE-F6-D |
Back-electrode sample stage feature a knob can be rotated to choose the measured cell for the multi-cell samples |
IV/QE measurement |
35mm*35mm |
Need to be customized based on the sample size and electrode position |
|
QE-F6-H |
Back-electrode sample gas sealing stage feature a knob can be rotated to choose the measured cell for the multi-cell samples |
IV/QE measurement |
35mm*35mm |
Need to be customized based on the sample size and electrode position, providing gas circulation environment |