Zolix 라만 롱패스 엣지 필터 Raman Long-Pass Edge Filter
Long-pass edge filter for Stokes Raman signal detection
스토크스 라만 신호 검출용 롱패스 엣지 필터
Description
DSR600 is a multifunctional experimental platform which is based on spectral response measurement. The system employs a turnkey integrated design, which can carry out Spectral Response, the QE, Reflectivity, Mapping testing functions automatically. It conforms to the national standard measurement method and is an essential tool for the study of spectral response of optoelectronic devices and materials. DSR600 series Characteristics Function: ■ Spectral Response ■ Bias Voltage Spectral Response ■ EQE, IQE ■ Reflective, Transmittance ■ Short Circuit Current Density ■ IV Measurement Large Spectral Range (200-2400nm optional) Large spectral range means that it is suitable for a variety of different samples, such as deep-ultraviolet detectors responding to the solar blind zone, solar cells, the near-infrared fiber sensors, and so on. All of them can be measured on the DSR600. Turnkey Design, Simple Maintenance The system uses substitution method of measuring principle, which is designed into Turnkey mode. Users do not need to debug the system before experiments. Routine maintenance is also very simple. The substitution method has been adopted as the spectral responsivity measurement standard method by the National Measurement Unit. Compared with the conventional detection methods, the substitution method is simple and has high accuracy for the system, avoiding systematic errors. For the substitution method detector system, the user just need to calibrate the Standard detector regularly. But for the conventional detector system, all of the parts of the system need to be calibrated, including the light source, monochromator, all of the optical component, that means the user have to split the system. Monitoring CCD The monitoring CCD is used for observing the probe light spot and positioning the sample accurately.
DSR600은 분광 응답 측정 기반의 다기능 실험 플랫폼으로, 턴키 통합 설계를 채택하여 분광 응답, QE, 반사율·투과율·흡수율, 헤이즈 측정 등을 수행할 수 있습니다.
Specifications
Total reflection optical path without aberration makes the measurement result more accurate.
Different photodetectors have different spectrum response range, so wide spectral range is very important for the detector responsivity measurement system to measure different photodetectors. The system designed in perfect reflection optical has better beam quality and spot uniformity than the system with transmission optical design.
In the transmission optical system, one of the important factors that determine the beam quality and spot uniformity is chromatism which originates in different wavelengths of monochromatic light having different refractivity for the optical material. And the wider spectral range , the more obvious the chromatism is. But in the perfect reflection optical system, it is not base on the refraction, there is no chromatism problem. So in the perfect reflection optical system, you can get the quality parallel spot or much small convergency spot .
Features:
Though the modulation method could reduce the impact of stray light and the background noise on the measurement, the fluctuation of light source is still impossible to eliminate. So in the system designed in modulation, the stability of light source is the main source for system noise. Adopt the high stability light source to keep the system high repeatability. The stability data for light source relative intensity.
|
Model |
DSR600-3111 |
DSR600-3121 |
|
|
Light Source |
Xenon |
Tungsten |
|
|
Spectral Range |
300-1700 nm |
400-2400nm |
|
|
Repeatability |
200-400 nm |
≥ 98% |
– |
|
400-1000 nm |
≥ 99% |
≥ 99% |
|
|
1000-1700 nm |
≥ 98% |
≥ 98% |
|
|
Data Acquaintance Unit |
Lock-in |
Lock-in |
|
|
Spot |
≤ 1 mm |
||